Ex. 1)
efficiency full load NfL = 95.10%
N3/4 = 98.81 %.
.........................................................
Ex. 2) R0^1 = 32.13 , R01 =41.13
X2^1 = 42.24 , X01 =70.24
R1^1 = 0.98 , Z01 =81.76
X1^1 = 3.04 , X02 =7.64
Z02 = 8.90 , R02 =4.47🤔🤔🤔🤔🤔🤔🤔🤔🤔🤨🤔

Ответить
@I_am_Parth
@I_am_Parth - 13.10.2020 18:33

Ex:-1) efficiency Full load NfL =95.10% N3/4:- 98.8%
-----------------1809----------------
Ex:-2) R0^1=32.1,R01=41.1
X2^1=42.2,X01=70.2
R1^1=0.98,Z01=81.1
X1^1= 3.0,X02=7.6
Z02=8.9,R02=4.1